Buy a cheap “clamp-on” current meter from Ebay (that can measure AC current) and place it around the LIVE wire only on the supply to the Caravan. While we always recommend calling a trained engineer to help with boiler problems, many technicians charge by the hour. Any ideas before I send pcb away for repair, to me a fuse constantly blowing would indicate a short but can't find anything.main fuse under consumer box is ok. The aptly named diverter valve diverts the water to either your radiators, hot water outlets or both – depending on what you’re demanding from it. This lightweight material has optimum thermal insulation properties. Cause. As my currents were all correct, this suggested that my problems lay with the Thermostats on the heating element. Currently the Truma AquaGo can only be installed by a trained Truma Dealer partner. To fix this, firstly you need to buy a “repair kit” from Ebay (or supplier of your choice). No power. Heat is distributed throughout the ’van by a Trumavent fan unit, which pumps warm air through pipes and vents fitted behind and underneath the[tl:gallery index=1 … Truma Combi Lamellas. (I modified an extension lead so that I could hook around the LIVE wire only to make current measurements safely. Considering this, if you are able to diagnose the issue and take a few preliminary steps before you book a repair, you could save the engineers time and … It is a duel fuel unit, which means that it runs on 240v mains electric and gas. Reset the tripped circuit breaker or replace a blown fuse. After checking the consumer unit and then checking the 5 amp fuse on the consumer unit it then works. Comment document.getElementById("comment").setAttribute( "id", "a4ef37f5bbe9aa8abb9a7e3af201a6ca" );document.getElementById("f825832f79").setAttribute( "id", "comment" ); Your email address will not be published. Also its a “special” thermostat – so you HAVE to use the OEM replacement – very expensive. A typical Truma configuration in older motorhomes consists of the Trumatic S3002 gas heater, complemented by an Ultraheat 230V electric heater. Do you think its the 12 volt supply that is at fault The Truma electric boiler consumes little electricity and operates almost silently. If you are lacking heat, by searching the Web, I found that there are several problems that seem to afflict these heaters 1) Relays not working: My model has settings at 500W, 1KW and 2KW. Water Heater not working on electric,Heaters - View more questions and answers on Campsite,Caravan,Motorhome,Forum,caravan talk, motorhome talk, ukcampsite Feedback We use cookies, by continuing to browse the site you are agreeing to … The water level is low: Maintain the water level in the boiler at half-full.The boiler's automatic filling system, controlled by the pressure-reducing valve, should … I’m still trying to figure out what to do about this – insulation behind the thermostat? Have you changed it when required? Truma Combi comfort. Fault found (I hope). Remedy. I was having problems with my heater. The replacment is better but still not brilliant! Operation without water; overtemperature protection switches the heating element off. Caravan front Window Stay breaking away at the window frame. You may well be running on electric, but some heat comes up that flue pipe and turns the thermostat off early. Good luck with the shower test, looking forward to hearing the results! Electrical problems. The new Truma Portal and the new Mediacenter is online. The currents should be: 0.5A, 4A and 8A respectively. ; Page 2: Table Of Contents 4 Pressure and Temperature Relief Valve (P&T safety valve) 5 Cowl for combustion air intake and exhaust gas discharge Operating instructions Filling the Truma … Self-service. Checked all out today when I got home and heating element has continuity and an ohms reading of roughly 61.the water heater won't work on gas or electric. After replacement the boiler side is ok on electric. NO, I don’t fix caravan heaters – but to help you here is how I fixed mine. Required fields are marked *. ... Truma heating systems come standard on many RV's straight from the manufacturer. Will be back in Sydney during this week, so … This indirect method is not a wonderfully efficient way of heating water - significantly less efficient than the 'kettle' method used for the traditional Truma B10/B14 "Ultrastore" boilers - nevertheless, it works (or SHOULD work) fairly well when air-heating is not being employed simultaneously. Page 1 Truma UltraRapid Hot Water System LPG and 230 V / 240 V Electric Storage Water Heater Operating instructions Page 4 Installation instructions Page 8 To be kept in the vehicle! The boiler doesn't have power: The circuit breaker or fuse controlling the furnace may have tripped or blown. If you have a dual mode (gas and electric) hot water system, and it works on gas but not in the electric mode, the heating element could be broken. UK Total Maintenance…. If this has happened, simply switch it on again and reset the … Safety is critical to Truma and these systems require compliance to specific international standards. In my case, I tested the power input to the caravan to confirm that all my relays were working correctly, with the caravan taking the correct amount of current for each heat setting. Could be first signs of the regulator failing, although the fridge and cooker are working the Truma has a high gas demand and will fail if there is not … Report. Automatic On-board Water Tank fill System (& Tracker) Part 1, Tony Sparks – The Electric Warrior is back ! Electric version of the Combi eco with integrated heating elements for gas, electric, and mixed modes. I replaced mine as it seemed to be switching off early. Newport, Shropshire, TF10, https://www.ukcampsite.co.uk/chatter/display_topic_threads.asp?ForumID=8&TopicID=305177&ThreadPage=1 . Also be aware of (in my case, Bailey Senator 6, Arizona), the room thermostat sitting over the flue. Learn More. I was having problems with my heater. Your Truma heating unit is responsible for the heating of your caravan. to the Ultraheat electric element which … PLEASE NOTE: As you need to disconnect the Gas Supply and the Gas Flue – you will need to find a handy Gas Engineer or “phone a friend”…. Truma heater not work on elec..Caravan Repairs, Servicing and Maintenance. If you have been caravanning for years, it’s easy to think that everybody already knows how to get the best performance out of a Truma Trumatic S3002. (below temperature). We passed on the Truma water heater, not for the reasons that you don't get all the hot water on demand, but because of our gray tank storage and more water into the tank just requires more dumping of the gray tank. Replace the safety guard, insulation, and access panel. How to get the best from your Truma Trumatic S3002 heater. From the point of view of the gas operation The heater should be room sealed so all of the combustion takes place outside of the van therefore safe to run overnight if neccesary. Better to relocate the thermostat, but where to put it ??? Truma Ultrastore Water Heaters 10L and 14L with and without the electric heataing element. If the relays are faulty, this can reduce the power of the heater. When the dealer, Vicount Motorhomes in Southampton, removed the boiler they noticed some scorching on the PCB where the 230v fuse is housed. It has also blown the 6.3a slow burn fuse on the 12v pcb. Oh yes, in addition to BOTH thermostats, you MUST replace the Gasket Seal on the Gas Flue. The two people working together are working in different areas of the warehouse so will be more than 2 … The electricity supply to the boiler may have turned off. Replacement thermostats and heating elements are easily available and can make your hot water system good as new. The AquaGo water heater worked one weekend, and then the next nothing. The green light on the control switch also comes on as it should. NO, I don’t fix caravan heaters – but to help you here is how I fixed mine. Heating System Accessories. Turn on the heater's circuit breaker. If water is discharging, this means the safety valve has opened due to too much pressure in the unit or too much heat. Due to the manufacturing variance, installation can take between 2-2.5 hours for a conventional water heater, 0.5-1 hour for a competitor on-demand unit. so it is important to check it each 6 months and … That takes you through the job, but I would have been happier with more detail, so after you have watched the video, you can follow my article below on how I did it…. If you are lacking heat, by searching the Web, I found that there are several problems that seem to afflict these heaters 1) Relays not working: My model has settings at 500W, 1KW and 2KW. The corrosion can be minimised by corrosion protection like an anode. The Ultra Heat is equipped with a fan that allows the warm air from the heater to be passed around the caravan via a system of pipes and the warm air is released through ‘butterfly’ … Your previous login credentials are no longer valid from 07.07.2020. Switch the Truma electric boiler off, wait ten minutes, fill it with water and switch the Truma electric boiler on again. Reconnect the power. Most electric elements that are submersed in water fail due to corrosion of the sheath enclosing the heating element. Bailey Senator Series 6 Water leak around the front lockers down at floor level adjacent to the Bulkhead. Use a Truma caravan heater. Treecrest14 - yes it has worked on AC in the past - but stopped working recently. Should the boiler pressure be too low (below 1 bar), then the boiler will fail to work, while high boiler pressure (over 2 bar), can put unnecessary strain on the boiler and … The water heater (Truma) sometimes will not work on Electric. Like. What do YOU Think? But it definitely has a faulty part, and it’s probably the diverter valve . You can check this yourself if you are “handy”. on Ebay. See this link for a start: https://www.ukcampsite.co.uk/chatter/display_topic_threads.asp?ForumID=8&TopicID=305177&ThreadPage=1 . Common Boiler Problems: Causes and Quick Fixes . print page keyboard_arrow_right back to top. A boiler not working that still provides heating is a brave boiler indeed. The gas heating works no problem as does the fan for the blown air system. Do truma HWS have a sacrificial anode? We work closely with our manufacturing partners to ensure a safe and reliable installation of our equipment and therefore do not allow unauthorized sales, installation or repair of our Truma systems. We have somehow developed a problem with our Truma combi boiler/heater. No code, other than with the hot water shortly after its on I get two quick, a space, two quick, a space, and then it … The boiler is insulated with a special expanded polypropylene (EPP) foam. Caravan Wheel Arch leaking water / Cracked / Damaged following “lost tyre” (damage from broken tyre). Press the red button—the high-temperature cutoff reset button—located above the upper thermostat. The water heats up ok on EHU; ie boiler ok on electric. Remove the insulation and the plastic safety guard, being careful not to touch any wires or electrical terminals. KJB - Not sure if it is the electric heating element or thermostat, Will need to check further. … Switch the Truma electric boiler off, wait ten minutes, fill it with water and switch the Truma electric boiler on again. In some cases, boilers stop working because of minor electrical problems – in many cases, people can resolve these issues themselves without a professional’s help. Truma said that this is a known, albeit uncommon, fault and supplied a new PCB which was duly fitted and the electric heating system is now working again. Check the Tundish to see if water is discharging. By William Grant Published: August 9, 2011 . Operation without water; overtemperature protection switches the heating element off. Remedy: Try twisting the black or red cap on the temperature pressure relief valve to try to reseat the valve. The water temperature drops by just 1°C per hour and reheating takes next to no time, … Ideally, the boiler in your home should have a boiler pressure of between 1-2 bar, preferably 1.5 bar – you can check the boiler pressure on the pressure gauge. For some reason though, the heater will not work on electric and blows the 10a fuse on the electobloc. Are you having problems with your Truma Caravan Heater not heating up ? Mandatory Electrical Inspections for Rental Property 2020 England. Where was I? We've narrowed it down (I think!) Herks - No switch as such to swap from gas to AC other than to select temperatures of 65c or 75c. We have the Trumatic S 3002p system which has both gas and electric heating with blown air. View Partners. © 2020 - Truma Gerätetechnik GmbH & Co. KG Putzbrunn, Truma heaters for caravans and motor homes, Truma iNet System: smart appliance control, Your career with Truma Gerätetechnik GmbH.